Site Navigation -

Tel: 01245 361578



RB3300 Code no. 171.20.051

ACU - RX 3000 System Control

RX 3000 Index Page


RB 3300 Amplifier Control Unit

The RB 3300 back amplifier unit is an accessory board designed to work with constant voltage amplifiers connected to the RX 3000 matrix system. The board is mounted on a chassis designed to mount in the rear of a 19" cabinet rack behind the associated power amplifier.
When installed on a RX 3000 system, the board can be used to switch the amplifier on/off, control the amplifier operation, activate a backup amplifier in the event of failure and monitor the amplifier output via a dedicated loudspeaker mounted on the
CP3100 control unit.
With an optional SB 3320 fault detection board fitted, the unit can be used to monitor the loudspeaker circuit, monitor the operation of the amplifier and switch in an overriding priority audio signal to bypass the RX 3000 matrix signal.
With an optional
LB 3340 digital automatic level control board fitted, the unit can be used to automatically control the ambient signal/noise ratio of a particular area. A day/night function enables a lower output level to be set during night time hours.


Specification

Audio input

Balanced 775mV (0dB) / 600ohms

Input impedance

7K ohms

Audio output

Balanced 775mV (0dB) <600ohms

Monitor bus output

Balanced 775mV (0dB) <600ohms

Monitoring voltage

25V, 50V, 75V and 100V line

Communication

RS-485

Power consumption (w/o options)

5V dc - 35mA(150mA
if RS485 line s/c).
12V dc - 30mA. 24V dc -65mA.

Dimensions (w h d)

483 x 44 x 40

Weight

5.4 kg.


Features

  •  
  • Balanced input.
  • Balanced output
  • Amplifier fault condition input.
  • Self-diagnosis (watchdog circuit).
  • Manual / automatic back-up amplifier switching.
  • Amplifier output monitoring.
  • Power status LED.
  • Board status LED.
  • Communications status LED.
  • Automatic level control (option LB 3340).
  • Loudspeaker circuit monitor (option SB 3320).
  • 19" rack mounting (rear of cabinet rack).

The RB 3300, SB 3320, and LB 3340 control boards can also be used independently from the RX 3000 system, with the same basic functions (amplifier-line diagnosis, automatic switch-on of the emergency amplifier, control of the ambient signal/noise ratio). Any emergency condition can be signalled from a distance using the specific output command.