EP5004
- 4 CHANNEL PROFESSIONAL POWER
AMPLIFIER
|
|
RCF
Current Products
- Acustica
Index
- EP5004
|
|
|
|
|
FEATURES
4 Channel amplifier 2U
4 x 550 Watt/4 Ohm
(2 x 1100 Watt/8 Ohm)
Flexible bridge mode
operation
4 independent inputs,
4 independent outputs
4 independent amplifiers
with centralized diagnosis
Equalization boards option
Thermal protection,
DC protection,
Short Circuit protection,
Current protection
Fast limiter Circuit
Main Voltage diagnosis,
in-out signal diagnosis
Compact design,
2 rack units
Ideal for
permanent installations
|
|
|
|
|
|
|
|
APPLICATION
ORIENTED
The EP5004 offers the System Engineer incredible
versatility. From small systems to more complex or
larger situations, the EP5004 provides a very cost
effective solution without compromising sound
quality. The amplifier is the optimum choice in
many situation, from a multi-zone installation to a
multi-way monitoring system. In PA systems, it is
possible to use 2 channels for left and right
signals and bridge the other two channels for
subwoofer application. The use of dedicated
equalization boards guarantees the optimized sonic
quality for each speaker without adding the cost of
expensive processors. Equalization boards fully
dedicated for the RCF Acustica Series Speaker
Systems are available. Muting and diagnosis are
available from the back panel.
POWER AND DYNAMIC
Each single amplifier is fully independent and
provides up to 550 Watt with a 4 Ohm load. Each
pair of amplifiers can independently operate in
bridge mode delivering up to 1100 Watt on an 8 Ohm
load. Our clip reduction system is dynamically
tracking the power supply rail values in order to
prevent clipping distortion which assures the
delivery of the maximum available power. Attack and
release time constants are accurately calculated to
prevent any "pumping" effect.
ANALOG AND DIGITAL
The signal path is fully analog for tighter bass
and clean transparent highs. Controls, protections
and diagnosis are digital: a proper mix respecting
sound quality.
PROTECTION AND DIAGNOSIS
The system's protection provides safe operation in
the most varied and demanding situations. The
output relays avoid transient situations at the
speaker output, this system guarantees both DC
current and short circuit protection for the
amplifier and speakers. The continuous and
intensive use of the amplifier is guaranteed with
continuous thermal monitoring; an optimised voltage
controlled double fan cooling system acts when
needed in a proportional way to the heat generated
from the output transistors. The thermal controls
act independently on the 4 amplifiers and on the
power supply transformer. 4 status LED's situated
on the front panel provide real time monitoring of
each channels working condition.
|
|
|
|
TECHNICAL
SPECIFICATIONS
|
|
FREQUENCY
RESPONSE
|
20
- 20.000 Hz
|
|
MAX
OUTPUT POWER
|
4
independent channels (8 Ohm) 350
W
|
|
|
4
independent channels (4 Ohm) 550
W
|
|
|
2
bridge channels (8 Ohm) 1100 W
|
|
DISTORTION
|
THD
20 - 20 KHz @ full power 0.07%
|
|
|
THD
20 - 20 KHz @ - 1dB under CLIP
0.02%
|
|
INPUTS
|
Neutrik
XLR & JACK
|
|
|
Sensitivity
4 dBu
|
|
OUTPUTS
|
Neutrik
SPEAKON (1+ 1- single channel, 2+ 1+
bridge)
|
|
|
Gain
32 dB
|
|
FRONT
PANEL
|
4
x gain controls
|
|
|
4
x status LED each channel
|
|
|
1
x equalisation board option
|
|
REAR
PANEL
|
Powercon
AC connector
|
|
|
4
x XLR inputs
|
|
|
4
x Jack Inputs
|
|
|
4
x Speakon Outputs
|
|
|
Diagnosis
board option
|
|
OPTIONS
|
Standard
diagnosis
|
|
|
RS485
diagnosis
|
|
|
Standard
Flat equalisation board
|
|
|
Speaker
dedicated equalisation boards
|
|
DIMENSIONS
|
88
H x 480 W 418 D (2 x 19" rack
units)
|
|
WEIGHT
|
17
Kg
|
|
|
|
APPLICATIONS
Theaters
and
auditoriums
Arenas
AV Presentations
Stadiums
Club Systems
Houses of Worship
Bars and restaurants
Theme parks
Cruise ships
Sound Reinforcement
in medium to large spaces
|
|

User Manual
|

Data
Sheet
|
|
|

Optional
filter module click image
C3108XEQ
- DATA
C3110XEQ
- DATA
|
|
|
|
|